ASP AEROFLEX™ AER

ASP EVOTECH® ECR

Medivators® DSD 201LT

Cycle Time

22 min Fastest Complete Cycle Time*1

30 min

28 min

Color touch-screen controls

Yes

Yes

No

Automated cleaning cycle**

No

Yes

No

Automated MRC / MEC testing

Yes

Yes

No

Test Strips

Not required

Not required

Required

Automatic Duodenoscope Detection & Cycle

Yes

No

No

Basins

1

2

2

Scopes per basin

1

1

1

Biocide***

ASP AERO-OPA™ Solution

Single Shot, CIDEX® OPA-C (Concentrate)

Reusable OPA or Rapicide Disinfectant

Automatic OPA Neutralization

Yes

NA

No

Continous leak test***

No

Yes

Yes

Automatic temperature control

Yes

Yes

Yes

Automatic locking lid

Yes

Yes

Yes

Automatic system self-disinfection

Yes

Yes

Yes

Installation

Included

Included

See manufacturer for details

Training

Included

Included

See manufacturer for details

Training

Included

Included

See manufacturer for details

Get a detailed comparison tailored to you


AP-2100098-1

*In countries where distributed. Includes wash, high-level disinfection, rinses, MRC testing and alcohol flush. For all qualified endoscopes except duodenoscopes which require additional time. Assuming nominal conditions for water pressure, flow rate and temperature.

** Does not eliminate bedside cleaning and may not eliminate manual cleaning; Health Care facilities should follow their own policies and procedures related to the reprocessing of endoscopes to ensure they are complying with all steps recommended by the device manufacturers and are consistent with current standards and guidelines. Not all endoscopes can be automatically cleaned but may be high-level disinfected. It is recommended that endoscopes with open/closed elevator wire channels be manually cleaned as per manufacturer's instructions in addition to using the cleaning cycle of the EVOTECH® System. Please refer to the EVOTECH® ECR User Guide and specific connection diagrams for more detailed information regarding cycle capabilities

***This product is not a sterilant. Ensure adequate ventilation and wear the appropriate PPE. Please refer to the ASP AERO-OPA™ Solution and CIDEX® OPA-C instructions for use for additional information.

****Automatic leak and blockage detection may not apply to all scopes or cycles. Please refer to the EVOTECH® ECR User’s Guide and specific connection diagrams for more detailed information regarding cycle capabilities.

The third-party trademarks used herein are the properties of their respective owners.